Clarke 7150715 운영 및 유지보수 지침 매뉴얼 - 페이지 7
{카테고리_이름} Clarke 7150715에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 7150715 13 페이지. Bore hole pump
The pump is equipped with a thermal-amperometric motor protector. In case
of overload, the motor protector shuts down the pump automatically. When
the motor has cooled the pump starts up again automatically. If the motor
protector steps in, it is absolutely necessary to locate and eliminate the cause
of the malfunction. (refer to troubleshooting on page 8).
NOTE: The water being pumped will be polluted if this pump becomes
damaged and lubricant within the pump escapes.
CARE & MAINTANENCE
WARNING: ELECTRIC SHOCK HAZARD! BEFORE CARRYING OUT ANY
MAINTENANCE OR CLEANING OPERATIONS, DISCONNECT THE PUMP
FROM THE POWER SUPPLY.
This pump does not require any particular maintenance and all repairs must be
carried out by an authorised service centre only.
After removing the pump from the water, drain and rinse with clean water.
To clean the suction filter, use a jet of clean water.
If the pump's turbines need replacement, take the pump to an authorised
service centre.
If the power supply cable is damaged it MUST be replaced by the manufacturer
or an authorised service centre.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
7