Clarke 7160047 운영 및 유지보수 지침 매뉴얼 - 페이지 8
{카테고리_이름} Clarke 7160047에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 7160047 13 페이지. 12&24v diesel fuel transfer pumps
FAULTFINDING
Problem
Pump fails to
operate.
Motor turns slowly
when starting.
Lack of flow delivery. Low level in the storage
Leakage from the
pump body.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Check
Check for good contact
between crocodile clips
and battery.
Check the switch is on and
that the fuse is not blown.
Pump rotor jammed.
Motor fault.
Low supply voltage.
tank.
Foot filter blocked.
Pump is positioned too high
above the storage tank.
By-pass valve blocked.
Air entering the pump via
the suction hose.
Narrowing of the suction
hose.
Low pump speed.
Suction tubing is resting on
the bottom of the tank.
Seal damaged.
8
Solution
Establish good contact.
Replace fuse or switch
on.
Check for possible
damage or obstruction
of the rotating parts.
Return to Clarke Service
Department for repair.
Check condition of
battery.
Refill the tank.
Clean out the filter.
Position the pump lower
in relation to the tank.
Return to Clarke Service
Department for repair.
Check the security of
hose connections.
Hose is damaged,
blocked.
Check the power supply.
Raise the tubing.
Return to Clarke Service
Department for repair.