Medium-Pressure Stub Pump
Pump Indications
Pump does not cycle
Pump will not prime
Pump cycles rapidly
Pump cycles continuously,
or slowly (once or twice/
hour)
External Leaks
Product leakage at outlet
hose
Product leakage at control
valve
Product leakage past
O-Ring (4) and visual at top
of Tube and Guide assembly
(17)
Product leakage past
O-Ring (6) and visual at
bottom of Tube and Guide
assembly (17)
Internal Leaks
Product leakage past piston
Wear Rings (13) and/or
O-Ring (15)
Product leakage past
Ball (12)
Product leakage past
Valve Disk (20)
Alemite, LLC
Troubleshooting Chart
Possible Problems
1. Air motor not operating properly
2. Pump tube jammed and/or contains loose
components
3. Insufficient air pressure
1. Excessive cycling speed
2. Pump leaking internally
Product source empty
1. Pump leaking internally
2. Pump leaking externally
3. Distribution system leaking
Hose connection not tightened sufficiently
Control valve connection to hose not tightened
sufficiently
1. Initial tightening of Tube and Guide
assembly (17) to Tube Adapter (5) not
sufficient
2. Foreign material between O-Ring (4), Tube
and Guide assembly (17), and
Tube Adapter (5)
3. Damaged O-Ring (4), Tube and Guide
assembly (17), or Tube Adapter (5)
1. Initial tightening of Tube and Guide
assembly (17) to Valve Seat (21) not
sufficient
2. Foreign material between O-Ring (6), Tube
and Guide assembly (17), or Valve Seat (21)
3. Damaged O-Ring (6), Tube and Guide
assembly (17), or Valve Seat (21)
1. Worn or damaged Wear Rings (13)
and/or O-Ring (15).
2. Worn or damaged Piston (14)
3. Contamination
1. Foreign material between Ball (12) and
Piston (14)
2. Damaged Ball (12)
3. Damaged Piston (14)
1. Foreign material between Valve Disk (20)
and Valve Seat (21)
2. Damaged Valve Disk (20)
3. Damaged Valve Seat (21)
4. Damaged Spring (19)
Changes Since Last Printing
Changed Air Motor Model 324300-M
1. Inspect air motor and rebuild or
replace as necessary
2. Rebuild pump tube
3. Increase air pressure
1. Reduce air pressure
2. See Internal Leaks
Replenish product
1. See Internal Leaks
2. See External Leaks
3. Correct leak
Tighten connection
Tighten connection
1. Tighten Tube Adapter (5) into Tube
and Guide assembly (17)
2. Disconnect Tube and Guide assembly
(17) from Tube Adapter (5). Clean and
inspect all parts. Locate and eliminate
source of foreign material.
3. Replace any damaged component
1. Tighten Valve Seat (21)
into Tube and Guide assembly (17)
2. Disconnect Valve Seat (21) from Tube
and Guide assembly (17). Clean and
inspect all parts. Locate and eliminate
source of foreign material.
3. Replace any damaged component
1. Disassemble pump, clean and inspect
Wear Rings (13) and O-Ring (15).
2. Inspect Piston (14).
3. Locate and eliminate source of foreign
material.
Disassemble pump, clean and inspect
seat areas. Check mating surfaces and
replace parts as necessary. Locate and
eliminate source of foreign material.
Disassemble pump, clean and inspect
seat areas. Check mating surfaces and
replace parts as necessary. Locate and
eliminate source of foreign material.
9
SER 8568-A4
Solution
Revision (7-05)