Clarke CGP870 운영 및 유지보수 지침 매뉴얼 - 페이지 9

{카테고리_이름} Clarke CGP870에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke CGP870 17 페이지. 870w grinder/slurry pump

Clarke CGP870 운영 및 유지보수 지침 매뉴얼

USING THE PUMP

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE
PUMP IF IT IS DAMAGED IN ANY WAY.
1. Plug in the pump and switch on the power supply.
• The pump will begin to drain water.
2. Run the pump continuously or remove from the water and store in a frost
free location if the water is likely to freeze.
3. Ensure the pump is switched off when water has stopped flowing.
• The pump should be able to clear water down to a residual depth of the
inlet port, In this situation, air and residual water may be seen escaping
from the discharge hose.
4. Disconnect from the power supply when the water has been pumped out.
Avoid running the pump continuously if the discharge hose has become
obstructed and water is not flowing.
5. DO NOT ALLOW THE PUMP TO RUN DRY
6. Disconnect the pump from the mains supply before placing it into or
removing it from the water.
7. NEVER insert your fingers into the pump whilst it is connected to the mains.
8. DO NOT use the pump if the water is liable to freeze, as this can cause
damage to the pump. Remove the pump from the water and store it in a
frost free location.

OVERLOAD PROTECTION

These pumps are fitted with automatic thermal overload protection.
If the pump overheats due to an obstruction in the pump, or pumping warm
water for example, it will shut off automatically.
Switch the pump OFF at the mains supply. Check for blockages and allow the
motor to cool (at least 5 minutes) by which time the cut-out will have reset.
Once the pump has cooled the pump will automatically restart.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
9