• It is not recommended that these pumps be used for pumping drinking
water, as there is a remote possibility of water contamination due to
leakage of pump lubricant should the pump malfunction or the oil seal
become damaged.
All HSE pumps are provided with a thermal overload cut-out, so that in the
event the pump becomes overheated (due to becoming blocked etc.) the
pump will shut off automatically. When the blockage has been cleared, the
thermal overload will cool down and re-set and the pump can be re-started.
OPERATION
CONNECTION AND LOCATION
1. Place the pump in a vertical position resting on a firm, flat surface. If this is
not available, sit the pump on timber or house bricks, but ensure they are
not likely to collapse. Never install the pump on sand, silt, mud or ground
that is likely to collapse.
Automatic versions should only be placed in a sump which is large enough
not to restrict the movement of the float switch. It is advisable to use a
strainer when using the pump as a sump pump.
2. Keep the pump clear of any
sediment by standing it on a
platform or brick or suspending
from a rope attached to the
handle if the pump is to be
used where there may be silt or
mud etc (e.g. garden ponds).
3. Connect the outlet to the
largest diameter hose
available, as any restrictions will
reduce capacity and put
further strain on the motor. The
outlet hose diameter for each
HSE pump is given in the
Technical Specification.
4. Ensure that the hose diameter is
equal to or greater than the diameter of the pump outlet if a long run of
discharge hose is being used.
5. Ensure the float has sufficient room to operate correctly if used in a
confined space such as a shaft or sump.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]