OVERVIEW
The Clarke HSE range of submersible pumps are of rugged and durable
construction, designed for long lasting continuous operation. They are suitable
for discharging pools, ponds, fountains, pits and any waste water drainage.
They can handle foul water containing sewage or other suspended material
including sand up to a maximum of 3kg/m
to an amount stated in the
3
specifications for each model. They may be used for pumping water,
(including seawater) or water containing small solids in suspension with
particle sizes of up to 6-10mm in diameter, dependant upon the size of pump.
The pumps are not suitable for handling inflammable, corrosive, explosive or
dangerous liquids.
The range includes models 130, 200, 300/301 & 360/361 as itemised in the
Technical Specification.
The HSE200 is fitted with a strainer to prevent the ingress of foreign matter.
Float switches are fitted to those models bearing an 'A' suffix, meaning the
pump will stop and restart automatically as the surrounding water level
changes. This makes them suitable for permanent or semi-permanent
installations, eg. installations where it is necessary to maintain a water at a
particular level without an operator in attendance.
As the water level rises, the switch will float and start the pump. As the water
level falls, so will the float switch, until it stops the pump. Float switches are
factory set to provide the correct ON-OFF switching mode.