Acorn Terrazzo-Ware SB Series 설치, 운영 및 유지보수 매뉴얼 - 페이지 3
{카테고리_이름} Acorn Terrazzo-Ware SB Series에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Acorn Terrazzo-Ware SB Series 3 페이지. Shower bases
IMPORTANT
Connection of Drain is made completed using Optional KDG2 - 2" Neoprene Flexible Drain
Gasket for 2" IPS waste pipe. Provides quick connection with inside caulk waste outlet on
shower base to 2" drain DWV plastic, Sch. 40, steel or X.H. (extra-heavy) cast iron pipe.
Requires no special tools gluing, threading or lead caulking.(Similar Industry Standard Drain
Gasket products are available off the shelf.)
RECOMMENDED PROCEDURE.
4
INSTALLATION INSTRUCTIONS:
1. Cut drain pipe to extend 1-3/8" into drain body.
Drain pipe should be even with top of gasket
when installation is completed. Position Shower
Base over 2" waste pipe making sure that pipe is
centered in drain body.
2. Lubricate gasket with soap solution and stretch
over 2" pipe with letters facing up.
3. Push gasket as far as possible into joint.
4. Using a hammer and caulking tool or 1/4" X 3/4" X
6" piece of wood instead of a caulking tool, work
around the gasket with a series of blows and
gradually drive gasket into drain body until it
bottoms. Drain pipe should be even with the top
of gasket.
5. Test connection before covering or concealing. To
test: plug 2" drain and fill receptor with water.
Check for leaks. Verify proper drainage. This
must be done before finishing walls.
NOTE:
As an alternate, drain connection made be using
Lead and Oakum installed per Industry Standards
of best Practice. Verify local code requirements.
2 5
WARNING!
MODELS WITH -TF TILING
FLANGE OPTIONS:
A. Do not let rough wall
Material Overlap Flange.
B. Do not attach flange to
building wall.
C. Let finished wall (tile,
etc.)overlap and rest on
shoulder.
Note:
For ADA models refer to
IMPORTANT on page 1
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
LATH,
PLASTER
BOARD, ETC.
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
TERRAZZO-WARE SHOWER BASES
2" WASTE PIPE
(BY OTHERS)
#2 & #3
Incorrect Method (A) (B)
DO NOT ATTACH
FLANGE TO WALL
A
3
TM
Optional KDG2 -2"
#1
OPTIONAL -KDG or
GASKET BY OTHERS
#4
Proper Install Method (C)
CAULKING
B
ACORN ENGINEERING FIELD SERVICE
1-3/8"
BASE
FINISHED
FLOOR
TILE, ETC.
C