Clarke 01605A 운영자 매뉴얼 - 페이지 12

{카테고리_이름} Clarke 01605A에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 01605A 20 페이지.

ENGLISH
EN
MAINTENANCE
2.
Keep the tops of the batteries clean and dry.
Keep the terminals and connectors clean.
To clean
the top of the batteries, use a damp cloth with a
weak solution of ammonia or bicarbonate
of soda
solution. To clean the terminals and connectors,
use a terminal and connector cleaning tool. Do
not allow ammonia or bicarbonate of soda to get
into batteries.
3.
Keep the batteries charged.
CAUTION!
The battery charger must be
reprogrammed when switching
from lead acid to AGM batteries.
See the Charger Manual for
instructions.
Do These Procedures When You End Your Work
Check the batteries and add distilled water as needed.
The correct level is within 1/4 inch of the bottom of the
tube in each cell.
CAUTION: Tap water may contain contaminants
that will damage batteries. Batter-
ies must be re-fi lled with distilled
water only.
WARNING: Lead acid batteries generate gases
which can cause an explosion.
NO SMOKING. Always wear eye
protection and protective clothing
when working near batteries.
Use a clean cloth and wipe the surface of the
machine.
-12- FORM NO. 56091084
®
Clarke
Operator's Manual (EN) - FUSION 20 / 20T