Directed Electronics Xpresskit DBALL 설치 매뉴얼 - 페이지 12
{카테고리_이름} Directed Electronics Xpresskit DBALL에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Directed Electronics Xpresskit DBALL 14 페이지. Databus all combo bypass module
Directed Electronics Xpresskit DBALL에 대해서도 마찬가지입니다: 설치 매뉴얼 (14 페이지)
Platform: DBALL
Firmware: GM5
LED Diagnostics and Troubleshooting
LED
Status
Module Programming
Solid red.
Flashes green
continuously.
Solid green for 3
seconds.
x3 secs
Active Ground While Running
Flashes green
continuously.
Off.
Inactive Ground While Running
Flashes green once
every second.
X1
Flashes green twice
every second.
X2
Flashes green 3 times
every second.
X3
The Mobile Integration Systems
Description
Waiting for the vehicle to be
started.
Vehicle has been successfully
detected.
Module has been successfully
programmed.
Ground out (GWR) is active.
N/A.
Lock function has been executed.
Unlock function has been
executed.
Trunk release function has been
executed.
Vehicle CAN Bus Integration System
Troubleshooting
Make sure that all the connections are correct (see
install sheet) and start the vehicle to begin the
programming sequence.
N/A.
N/A.
N/A.
The Ground While Running (status) wire is incorrectly
connected. Refer to the wiring diagram to make the right
connections.
If it does not flash, the bypass module did not receive the
signal. Verify the connections between the bypass and
the remote starter module.
If it does not flash, the bypass module did not receive the
signal. Verify the connections between the bypass and
the remote starter module.
If it does not flash, the bypass module did not receive the
signal. Verify the connections between the bypass and
the remote starter module.
© 2010 Directed Electronics. All rights reserved.
Rev.: 20101103
Page 12