Directed Electronics Xpresskit DBALL 설치 매뉴얼 - 페이지 10
{카테고리_이름} Directed Electronics Xpresskit DBALL에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Directed Electronics Xpresskit DBALL 14 페이지. Databus all combo bypass module
Directed Electronics Xpresskit DBALL에 대해서도 마찬가지입니다: 설치 매뉴얼 (14 페이지)
Platform: DBALL/DBALL2
Firmware: GM5 Remote Start Ready (RSR) Installation
LED
Status
Active Ground While Running
Flashes green
Flashes
Flashes
Flashes red & orange
Flashes
Flashes green quickly
D2D & W2W Commands
Flashes orange x1
Flashes x1
Flashes orange x2
Flashes x2
Flashes orange x3
Flashes x3
Flashes x4
Flashes orange x4
Flashes orange x5
Flashes x5
Parking Light Error Codes
The parking lights on your vehicle will flash a specific number of times 3 seconds following an unscheduled shutdown or
failure to start. Each flashing pattern is described below.
Flashes
Diagnostic
1
Runtime expired.
2
Over-rev shutdown.
3
Low/No RPM.
4
Transmitter shutdown.
5
Brake shutdown.
6
Hood shutdown/Remote start safety override switch is ON*.
7
Remote start safety override switch is ON*.
* If the vehicle hood status is supported through data, safety override switch input will report 7 flashes.
Description
GROUND OUT ON (GWR)
command received.
IGNITION ON command
received.
START ON command received.
Lock command received.
Unlock command received.
Trunk command received.
Aux1 command received.
Aux2 command received.
Troubleshooting
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
If the bypass module fails to flash, it means the module did
not receive the signal. Commands can come from RF, D2D
or W2W.
Rev.: 20150626
Page 10