CTEK MXS 10 매뉴얼 - 페이지 2
{카테고리_이름} CTEK MXS 10에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CTEK MXS 10 6 페이지. Fully automatic
CTEK MXS 10에 대해서도 마찬가지입니다: 사용자 설명서 (2 페이지), 사용자 설명서 (7 페이지), 사용 설명서 (20 페이지)

CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Battery
Program
Size (Ah)
Normal battery program
20–300Ah
14.4V/10A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
AGM battery program 14.7V/10A
AGM
20–300Ah
Use for AGM batteries.
Recond program 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime
and capacity. The Recond program
RECOND
20–300Ah
adds STEP 6 to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
Supply program 13.6V/10A
Use as 12V power supply or use for
float maintenance charging when 100%
20–300Ah
capacity of the battery is required.
Supply program activates step 7 without
time or voltage limitation.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
4 • EN
Explanation
Temp range
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the batterys
positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
STEP 1: ...is seriosly sulphated and may need to be replaced.
STEP 2: ...can not accept charge and may need to be replaced.
STEP 5: ...can not keep charge and may need to be replaced.
POWER LAMP
If the power lamp is lit with a:
1. STEAdY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery in 2 minutes.
TEMPERATURE SENSOR
The MXS 10 is equipped with an external temperature sensor. The tempera-
ture sensor is attachable. If so, the charger will compensate voltage accor-
ding to ambient temperature. Activated temperature sensor will be indicated
by a lit temperature sensor indicator lamp.
REAdY TO USE
The table shows the estimated time for empty battery to 80% charge
BATTERY SIZE (Ah)
20Ah
50Ah
100Ah
200Ah
TIME TO 80% CHARGEd
2h
5h
10h
20h