TROUBLE SHOOTING
LED
OPERATION
Steady ON System
Check
Steady
OFF
2 Flashes
No flame
detected
3 Flashes
High limit
switch failure
(unit has
overheated)
4 Flashes
Flame sensor
Failure
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLE SHOOTING
System performing self test. No action required.
No action required.
Heater fails to start.
1. Check fuel level
2.
Check the mains plug is correctly fitted and that the
fuse inside it has not blown.
3. Return to Clarke service department for repair.
Make sure heater is cooled down,
1. Make sure that the power switch is set to the OFF
position.
2. Wait 5 minutes
3. Start heater by setting the power switch to the ON
position.
Return to Clarke service department for repair.