ELECTRICAL CONNECTIONS
DEVIL 6003 (3KW) HEATER UNIT
This model is provided with a 13 amp BS 1363 plug, fitted with a 13amp fuse and
MUST be connected to a standard, 230 Volt (50Hz) electrical supply, preferably
through an approved plug, or a suitably fused isolator switch.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead should be wired up in accordance
with the following colour code:
As the colours of the flexible cable of this appliance may not correspond with
the coloured markings identifying terminals in your plug, proceed as follows:
•
Connect the GREEN & YELLOW coloured cord to the plug
terminal marked with a letter E or Earth symbol "
GREEN or GREEN & YELLOW.
•
Connect the BROWN coloured cord to the plug terminal
marked a letter "L" or coloured RED.
•
Connect the BLUE coloured cord to the plug terminal marked
a letter "N" or coloured BLACK
If this appliance is found to be fitted with a plug which is moulded on to the
electric cable (i.e. non-rewireable) please note:
1. The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the
correct replacement is used (as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local Clarke dealer
or most electrical stockists.
FUSE RATING
The fuse in the plug must be replaced with one of the same rating and this
replacement must be ASTA approved to BS1362.
We strongly recommend that this machine is connected to the mains supply
via a Residual Current Device (RCD).
E
Green & Yellow - Earth
Blue
-
Neutral
Brown
-
Live
6