Clarke Devil 6009 운영 및 유지보수 지침 매뉴얼 - 페이지 9

{카테고리_이름} Clarke Devil 6009에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke Devil 6009 20 페이지. Electric fan heaters
Clarke Devil 6009에 대해서도 마찬가지입니다: 운영 및 유지보수 지침 매뉴얼 (20 페이지)

Clarke Devil 6009 운영 및 유지보수 지침 매뉴얼
When using the heater for the first time a slight emission of smoke may be
noticed. This is quite normal and soon stops. It is caused by residual traces of
oil remaining on the element from production.
After use, turn the thermostat to the OFF position and turn the selector switch
to the Fan Only position, and leave the unit to cool down for a couple of
minutes.
5KW, 9KW &15KW HEATERS
The 5 & 9kw units have a three position twist control for FAN only, and FAN plus
either half or full heat output. The 15kw unit has a four position control;- FAN
only, FAN + 1/3, FAN + 2/3 & FAN + full heat output. A thermostatic
temperature control is also provided for fine control of heat output at a
constant pre-set temperature.
Reset
3-position fan speed / temperature control
Thermostatic temperature control
Should the unit overheat, a thermal cutout will operate, shutting down the
unit. If this happens, allow a period of time for the unit to cool (approx. 10
minutes) before pressing the RESET using a suitable tool, and restarting the
unit.
When switching the unit OFF, it is strongly recommended that the unit is run in
the FAN ONLY mode for approx. 10 minutes, in order to cool the heating
elements, before switching OFF completely and finally disconnecting from
the mains supply.
The thermal cutout may also operate if the heater is shut down without
allowing to cool sufficiently. If, subsequently, the machine fails to start, press
the RESET using a suitable tool and try again.
9