FAULT CODE DISPLAY

The digital display can show the following fault codes.
FAULT CODE
FO:- Operation error
F1:- Photocell error
F2:- Temperature
control sensor error
F3:-Thermostat error
LO
CH
HEATER SHUT DOWN & RE-STARTING
1. Set the power switch to the OFF position but do not unplug from the mains.
NOTE: When the heater is shut down, the fan will continue running for 5
minutes to expel hot air and cool the casing. For this reason the
heater should not be unplugged.
2. Only for extended shutdown should the heater be unplugged from the
mains supply.
3. If re-starting, wait 10 seconds after shutting off the heater before re-starting.
4. Set the power switch to the ON position and follow the startup procedure
above.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
CAUSE
1. Heater is switched on
before being plugged
in.
1. No fuel
2. Fuel is contaminated
3. Photocell is dirty or
damaged.
4. Fuel Filter is dirty.
5. Ignition error
1. Damaged cable
2. Sensor is damaged.
1. Internal parts over
heating.
2. Anti-tilting sensor
activated.
1. External temperature
o
below -9
C
1. Air temperature over
o
55
C.
12
SOLUTION
1. Disconnect from power
supply, switch off and
then plug in again
before switching on.
1. Switch off and refill the
tank.
2. Switch off, empty and
refill the fuel tank. Clean
the filter with clean fuel.
3.Contact your dealer.
4. Clean filter.
5. Contact your dealer.
1. Contact your dealer.
2. Contact your dealer.
1. Turn the heater off and
wait until it has cooled
down.
2. Reposition heater on a
level surface.
1. Wait for normal
temperature conditions
1. Wait for normal
temperature conditions