Fuel Filter
Removal of the fuel filter should it become blocked or contaminated, and require
cleaning, involves the removal of the burner head complete. The fuel pipe,
complete with filter, may then be detached, cleaned, using a good quality
solvent, and dried with compressed air. It is recommended however, that if the
filter becomes blocked, the complete assembly - fuel pipe with filter- should be
renewed.
General
It should be noted that should the heater be used with Diesel oil or 35 second oil,
servicing will need to be more frequent, due to the fact that these fuels do not burn
as cleanly as paraffin, and some 'sooting up' will therefore occur.
It is recommended, that paraffin be used wherever possible
Storage
Drain all fuel from tank before storing.
1. Drain the fuel tank completely and add approximately one gallon of clean
paraffin. Attach the fuel cap and move the heater forwards and backwards
to circulate the fuel. Remove fuel cap or drain plug and drain tank completely
2. Replace fuel cap or drain plug and properly dispose of the old and dirty fuel.
3. Store the heater in a dry location free from corrosive fumes and dust.
4. Do not store kerosene over summer months for next seasons usage.