Clarke CSB20B 운영 및 유지 관리 지침 - 페이지 6

{카테고리_이름} Clarke CSB20B에 대한 운영 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke CSB20B 6 페이지. Shot blast cabinet
Clarke CSB20B에 대해서도 마찬가지입니다: 사용자 지침 (13 페이지)

Clarke CSB20B 운영 및 유지 관리 지침
Replace the grid, ensuring the feet face
downwards with the cut away section at
the right hand rear of the cabinet. The
pick up hose should be routed throught
the gap made by the cut away portion
of the grid.
Insert the circular foam filter into the recess
in the Air Vent Cover, and attach the cover
to the rear of the cabinet as shown in Fig.4,
having first prised out the plastic bung from
the vent hole.
Finally, connect the air supply to the extended
nut shown in Fig.5. Use of the PTFE tape supplied
with ensure an airtight seal.
The air supply should be dry, and capable of
delivering a minimum of 10 cuft/min at 100 lbf/in

OPERATION

Plug the transformer into the power supply and switch the power ON. Switch the
lamp ON by pushing the rocker switch on the switch box 'I'. Switch OFF by pushing
'O'.
Ensure all air connections are secure, and the pick up is correctly located beneath
the grid, before filling the cabinet with abrasive media. Do not fill higher than the
level of the grid.
NOTE:
PTFE tape is provided which may be used on the threads of the various connectors
to ensure an airtight connection.
Select the ceramic abrasive nozzle to produce the jet required for the abrasive
media being used, and assemble according to the instructions given below.
Place the object to be cleaned in the cabinet, and close the lid, securing with the
two swivel clips.
If you are using a vacuum extraction device, turn it on before turning on the air
supply. Set the pressure to the required value, but not higher than 100lbf/in
check to ensure there are no air leaks. Should there be any, turn off the air supply
and repair where necessary, before turning the supply back on. Pull the trigger on
the gun and proceed to blast the object to be cleaned.
Keep the jet facing the object and away from the clear plastic lid. Do not allow
the jet to train on the rubber gloves, the air hose within the cabinet or the fluorescent
lamp.
When completed, turn off the air supply first, and, as a precautionary measure,
pull the trigger before opening the lid.
Fig.5
2
2
5
NOTES:
Fig.4
T here are no hard or fast rules governing nozzle sizes and air pressures used with
different abrasives. With experience and experimentation you will quickly learn
the best combinations for the required result.
On more delicate parts, start with minimal air pressure to avoid unnecessary
peening or excessive abrasion, and work up to a setting to produce the desired
finish.
Should any abrasive be spilled, ensure it is cleaned up immediately, as its slippery
properties can be extremely hazardous.
Replacing the Abrasive Nozzle
Ensure the air supply is disconnected before performing this operation.
1.
Pull the trigger of the gun as a precautionary measure.
2.
Unscrew the End Cap and withdraw the ceramic nozzle.
, and
3.
Replace with the nozzle of your choice and carefully thread the end cap
back on to the gun, taking great care NOT to cross thread the fine thread.
NOTE:
Should it be necessary to change the Air Nozzle, first remove the abrasive nozzle
as described above. An box spanner will be required to unscrew and withdraw
the air nozzle.
Fig.6
6