TROUBLESHOOTING:
PROBLEM
1. SET POINT DIFFICULT TO SET OR
CANNOT BE REACHED
2. DOES NOT MAINTAIN OUTLET
TEMPERATURE OR CHANGES
OVER TIME
3. DISCHARGE TEMPERATURE TOO
HOT OR TOO COLD
4. NO FLOW FROM VALVE
Acorn Controls
Division of Acorn Engineering Company
Manual #7802-116-000
SHOWERHEAD
COLD
WATER
SUPPLY
SV16 SHOWER
VALVE
SUPPLY TEMPS NOT WITHIN
SPECIFIED LIMITS
HOT AND COLD SUPPLIES ARE
REVERSED
FLUCTUATION IN SUPPLY
PRESSURES
FILTERS BLOCKED WITH DEBRIS
VALVE NOT ADJUSTED PROPERLY
HOT OR COLD SUPPLY FAILURE
OR SHUTOFFS CLOSED
CHECK FILTERS BLOCKED WITH
DEBRIS
SV16 Installation & Operation Manual
SHOWERHEAD
DIVERTER
VALVE
HOT
WATER
SUPPLY
TYPICAL PIPING w/ HANDHELD SHOWER
CAUSE
, A member of Morris Group International
®
HANDHELD SUPPLY
CONNECTION
COLD
WATER
SUPPLY
SV16 SHOWER
VALVE
SOLUTION
CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET
REINSTALL VALVE WITH SUPPLIES
CONNECTED TO MARKED INLETS
CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET
CLEAN FILTERS
READJUST VALVE TEMPERATURE PER
INSTALLATION INSTRUCTIONS
OPEN SHUTOFFS OR RESTORE HOT
AND COLD SUPPLIES
CLEAN FILTERS
™