HOW A FUSION
The Fusion
is simple in design, yet advanced in its wastewater
®
treatment ability. The design has been refined over many years of
intense research and development in an effort to perfect this superior
treatment system. Fusion
systems are 90% - 95% efficient at treating
®
wastewater. This is nearly twice as effective as a traditional septic tank,
which is approximately 50% efficient. This high degree of treatment
helps to protect both your personal property and the environment.
The Fusion
utilizes a combination of anaerobic (without oxygen) and
®
aerobic (with oxygen) biological processes to treat wastewater. As
Figure 1 - The following diagram will help you to better understand the process:
Inlet Pipe
Tank
Sedimentation
Chamber
Figure 2 - Schematic diagram of the Fusion
SETTLING CHAMBER
ANAEROBIC CHAMBER
INLET
2" DIAMETER
BACKWASH PIPE
Top View
SERIES TREATMENT SYSTEM WORKS
®
Anaerobic
Filtration Chamber
Treatment System
®
AEROBIC CHAMBER
OUTLET
1/2" AIRLINE ADAPTER
SK2850A
© Copyright 2014. All rights reserved.
wastewater enters the Fusion
biological organisms operating within the unit. The first chamber serves
to separate grease and large solids from the liquid. In the second
chamber, plastic media with large surface areas are used to increase
contact between water and beneficial bacteria to optimize treatment. A
single port blower is used to move air (oxygen) into the third chamber
for the aerobic process. The final effluent leaving the system will have
been treated to secondary quality effluent.
Recirculation Line
Aerobic Contact
Filtration Chmber
18 11/32 (466 mm)
H. W. L
W. L
2
, it is broken down and becomes food for
®
Outlet Pipe
Clean Water
Storage Chamber
20 95/256 (517 mm)
H. W. L
W. L
118 7/8 (3019 mm)
Side View
SK2850B