the user. Configure Link Alarm DIP switch as "Enabled" status, it
provides users transparent link indication between two network
devices interconnected by WAC-2012.
If Link Alarm is disabled, the UTP and fiber port will link up based
on their individual linking condition. Furthermore, if the fiber port
link is down during the operation, the UTP port link will not be
turned into the "Down" status, and vice versa.
7. LED Description
LED
Color
Function
PWR
Green
Lit when power is available.
PW T1
Green
Lit when TB1 on Terminal Block powers up.
PW T2
Green
Lit when TB2 on Terminal Block powers up.
Lit when TP port link is up.
Blinking when TP port is receiving and transmitting
Green
TP
data.
Off when TP port link is down.
Link/ACT
Blinking when the port link down caused by Fiber port
Orange
in case Link Alarm is enabled.
Lit when TP 100M port link is up.
Speed
Green
Off when TP 10M port link is up or no port link exists.
Lit when TP port works in full-duplex mode.
FDX
Green
Off when TP port works in half-duplex mode.
Lit when Fiber port link is up.
Blinking when Fiber port is receiving and transmitting
Green
F/O
data.
Off when Fiber port link is down.
Link/ACT
Blinking when the port link down caused by TP port in
Orange
case Link Alarm is enabled.
Lit when TP/Fiber port link is down and two power
sources are available, or TP/Fiber port link is down
and only one power source is available. (This
indication only works when PIN 8 and PIN 9 on the DIP
Switch are set to "Enable".)
PWR/Port
Orange
Status
Blinking when the redundancy system works
abnormally (only one power source is available) and
port links work normally.
Off when two power sources are available and port
links work normally.
8. Technical Specifications
Standards
IEEE 802.3, 802.3u
1 X 10/100Base-TX RJ-45 connector
Interface
1 X 100Base-FX SC/ST F/O port or SFP slot
LED
PWR, PW T1, PW T2, FDX, Speed, TP Link/ACT,
F/O Link/ACT, and PWR/Port Status
DC Input Voltage: 12~48V DC,
Power
AC-DC 12V Power Jack x 1,
DC Power Input x 2 on Terminal Block
Power
2.88W (Max.)
Consumption
Shipping Weight
0.295KG
105mm(W)X93mm(D)X35mm(H)
Dimensions
Temperature
Operating: -20ºC~60ºC
Storage: -20ºC~70ºC
5%~90% RH non-condensing
Humidity
EMC Safety
FCC Part 15 Class A, CE
TP:
Cat. 5 UTP cable
Media
Fiber:
50/125, 62.5/125m multi-mode fiber
9/125m single-mode fiber
*Please contact us for further reports and updates.
9. Fiber Transceiver Information
100M Multi-Mode:
TYPE
BTFC
Connector Type
SC
Wavelength
1310nm
Typical Distance
2Km
Min/Max TX PWR
-20.0dBm/-14.0dBm -20.0dBm/-14.0dBm
Sensitivity
-31.0dBm
-31.0dBm
Link Budget
11.0dB
100M Single-Mode:
TYPE
BTFC(SM-30) BTFC(SM-50) BTFC(SM-80) BTFC(SM-100)
Connector Type
SC
SC
Wavelength
1310nm
1310nm
Typical
30Km
50Km
Distance
Min TX PWR
-15.0dBm
-5.0dBm
Max TX PWR
-8.0dBm
0dBm
Sensitivity
-34.0dBm
-35.0dBm
Link Budget
19.0dB
30.0dB
100M Wave-Length WDM:
TYPE
W2A(SM-20)
W2B(SM-20)
Connector Type
SC
SC
TX Wavelength
1310nm
1550nm
RX Wavelength
1550nm
1310nm
Typical Distance
20 Km
20 Km
Min TX PWR
-14.0dBm
-14.0dBm
Max TX PWR
-8.0dBm
-8.0dBm
Sensitivity
-31.0dBm
-31.0dBm
Link Budget
17.0 dB
17.0 dB
NOTE: Specifications may change without prior notice.
Contact Information
Connection Technology Systems INC (CTS)
18F-6, No.79, Sec.1, Xintai 5th Rd., Xizhi Dist.,
New Taipei City 221, TAIWAN, R.O.C.
TEL: +886 2 26989661 FAX: +886 2 26989662
BTFT
ST
1310nm
2Km
11.0dB
SC
SC
1310nm
1550nm
80Km
100Km
0dBm
-5.0dBm
5.0dBm
0dBm
-36.0dBm
-35.0dBm
36.0dB
30.0dB
W2A(SM-40) W2B(SM-40)
SC
SC
1310nm
1550nm
1550nm
1310nm
40 Km
40 Km
-8.0dBm
-8.0dBm
0dBm
0dBm
-34.0dBm
-34.0dBm
26.0 dB
26.0 dB
WAC-2012 SERIES
10/100Base-TX to
100Base-FX Fast Ethernet
Media Converter
User's Guide