Operating environment
The x3630 M4 server is supported in the following environment:
Air temperature
Server on: 5 °C - 40 °C (41.0 °F - 104 °F); altitude: 0 - 915 m (3,000 ft).
Server on: 5 °C - 32 °C (41.0 °F - 89.6 °F); altitude: 915 - 2,134 m (7,000 ft).
Server on: 5 °C - 28 °C (41.0 °F - 82.4 °F); altitude: 2,134 - 3,050 m (10,000 ft).
Server off: 5 °C - 45 °C (41.0 °F - 113 °F).
Shipment: -40 °C - 60 °C (-40 °F - 140 °F).
Humidity:
Server on: 8% - 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr.
Server off: 8% - 80%, maximum dew point 27 °C.
Shipment: 5% - 100%.
Design to ASHRAE Class A3, ambient of 35 °C - 40 °C, with relaxed support:
Support cloud like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst case workload and configuration
result in system shutdown or design exposure at 40 °C.
Electrical
Models with 900 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 10 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5 A
Input kilovolt-amperes (kVA) (approximately):
Models with 750 W hot-swap power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 8.9 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
Maximum configuration: 0.90 kVA
Models with 550 W hot-swap power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 6.5 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.12 kVA
Maximum configuration: 0.66 kVA
BTU output
Minimum configuration: 406 Btu/hr (119 watts)
Maximum configuration: 3480 Btu/hr (1020 watts)
Noise level
6.6 bels (operating).
6.6 bels (idle).

Warranty options

The x3630 M4 has a three-year warranty with 24x7 standard call center support and 9x5 Next Business
Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-
warranty maintenance agreements, with a well-defined scope of services, including service hours,
response time, term of service, and service agreement terms and conditions.
System x3630 M4 (E5-2400)
Minimum configuration: 0.15 kVA
Maximum configuration: 1.02 kVA
30