Lenovo System x3750 M4 설치 지침 매뉴얼 - 페이지 18
{카테고리_이름} Lenovo System x3750 M4에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Lenovo System x3750 M4 30 페이지. 4-socket server
Lenovo System x3750 M4에 대해서도 마찬가지입니다: 제품 설명서 (47 페이지)
Securing the cables with the hook-and-loop fasteners
This topic provides information about securing the cables with the hook-and-loop fasteners.
Cables must be bundled with hook-and-loop fasteners for proper movement of the cable management arm.
Notes:
1. Make sure the cables do not sag below the U space so they will not get caught on the lower servers.
2. Allow slack in all cables to avoid tension in the cables as the cable management arm moves.
3. Pull the server in and out of the rack twice to make sure the cables are routed correctly and to ensure
there is no strain on any cables while sliding the server in and out of the rack.
Velcro strap
Securing the cable management arm and the server in the rack for
shipping
This topic provides information about how to secure the cable management arm and the server in the
rack for shipping.
To secure the cable management arm and the server in the rack for shipping (if the shipping the rack with the
server installed or if you are in a vibration-prone area).
1. Insert the M6 screws to the rear of the slides.
2. Use a cable tie to secure the free end of the cable management arm to the rack, if needed.
14
Lenovo System x3750 M4 Rack Installation Instructions
Rack Rear