Securing the cables with the hook-and-loop fasteners

This topic provides information about securing the cables with the hook-and-loop fasteners.
Cables must be bundled with hook-and-loop fasteners for proper movement of the cable management arm.
Notes:
1. Make sure the cables do not sag below the U space so they will not get caught on the lower servers.
2. Allow slack in all cables to avoid tension in the cables as the cable management arm moves.
3. Pull the server in and out of the rack twice to make sure the cables are routed correctly and to ensure
there is no strain on any cables while sliding the server in and out of the rack.
Velcro strap
Securing the cable management arm and the server in the rack for
shipping
This topic provides information about how to secure the cable management arm and the server in the
rack for shipping.
To secure the cable management arm and the server in the rack for shipping (if the shipping the rack with the
server installed or if you are in a vibration-prone area).
1. Insert the M6 screws to the rear of the slides.
2. Use a cable tie to secure the free end of the cable management arm to the rack, if needed.
14
Lenovo System x3750 M4 Rack Installation Instructions
Rack Rear