Rack installation
The G8272 switch includes a 2-post rack mount kit.
For 4-post rack installations, the G8272 switch supports the optional adjustable 19-inch, 4-post rail kit and
the air inlet duct (optional for the 4-post rail kit; supported only with the models with rear to front airflow).
When the G8272 switch (front to rear airflow) is installed in the Intelligent Cluster Rack (Machine
Type 1410) or Enterprise Rack (Machine Type 9363) as a part of a NeXtScale System solution, the
recessed 19-inch 4-post rail kit is required.
The following table lists rack installation options for the G8272 switches with rear to front and front to rear
airflow.
Table 10. Rack installation options
Description
Rear to front airflow (7159-HCW)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit
Air Inlet Duct for 487 mm RackSwitch
Front to rear airflow (7159-HCV)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit
Lenovo RackSwitch Recessed 19" 4 Post Rail Kit
Physical specifications
The G8272 switch features the following physical specifications:
Height: 44 mm (1.7 in.)
Width: 440 mm (17.3 in.)
Depth: 487 mm (19.2 in.)
Weight: 9.1 kg (20.0 lb)
Operating environment
The G8272 switch is supported in the following operating environment:
Temperature: 0 - 40 ºC (32 - 104 ºF).
Relative humidity: Non-condensing, 10 - 90%
Altitude: Up to 2,000 m (6,561 feet)
Acoustic noise: Less than 72 dB
Airflow: Front-to-rear or rear-to-front cooling with variable speed fans for reduced power draw
Electrical input: 50 - 60 Hz, 100 - 240 V AC auto-switching
Electrical power
Typical: 123 W
Maximum: 240 W
Heat dissipation
Typical: 420 BTU/hour
Maximum: 820 BTU/hour
Warranty and maintenance
Lenovo RackSwitch G8272
Part
Feature
number
code
00D6185
A3KP
00FM507
ASTN
00D6185
A3KP
00CG089
A51M