{카테고리_이름} Nikon Nivo 3.C에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Nikon Nivo 3.C 32 페이지. Hardware

Nikon Nivo 3.C 사용 설명서
2
Preparation
5.
6.
7.

Centering using the laser plummet

Note – Do NOT look into the laser directly.
Note – If you require high accuracy, check and adjust the laser plummet before you
center the instrument. For detailed instructions, see
Circular Level, page
1.
2.
3.
4.
5.
6.
7.
8.
1 4
Total Station Nivo Series Instruction Manual
Use the electronic level to level the instrument. For detailed instructions, see
Leveling, page
15.
Look through the optical plummet to check that the image of the station point is
still in the center of the reticle mark.
If the station point is off center, do one of the following:
If the station point is slightly off center, loosen the tripod mounting screw
and then center the instrument on the tripod. Use only direct movement to
center the instrument. Do not rotate it.
When the instrument is centered, tighten the mounting screw.
If the displacement of the station point is major, repeat this procedure
from Step 2.
30.
Set up the instrument on the tripod. For detailed instructions, see
Tripod, page
13.
Turn on the laser plummet.
Align the laser pointer to the station point. To do this, turn the leveling screws
until the laser pointer is over the station point.
While supporting the tripod head with one hand, loosen the tripod leg clamps
and adjust the lengths or the legs until the air bubble is the center of the circular
level.
Tighten the tripod leg clamps.
Use the electronic level to level the instrument. For detailed instructions, see
Leveling, page
15.
Check the laser pointer is over the station point.
If the station point is off center, do one of the following:
If the station point is slightly off center, loosen the tripod mounting screw
and then center the instrument on the tripod. Use only direct movement to
center the instrument. Do not rotate it.
When the instrument is centered, tighten the mounting screw.
If the displacement of the station point is major, repeat this procedure
from Step 2
Checking and Adjusting the