1.0 introduction

This document contains specific information regarding the
safe installation, operating and maintenance of Vertical In-Line
pumps and should be read and understood by installing, oper-
ating and maintenance personnel. The equipment supplied has
been designed and constructed to be safe and without risk to
health and safety when properly installed, operated and main-
tained. The following instructions must be strictly adhered to.
If clarification is needed on any point please contact Armstrong
quoting the equipment serial number.
warning symbols
Safety instruction where an electrical hazard is involved.
Safety instruction where non-compliance would affect
safety risk.
A
Safety instruction relating to safe operation of the
equipment. (attention)
fig. 1 Noise levels.
odp
frame
designation
hp
0.75 – 1
140
1.5 – 2
180
3 – 5
210
7.5 – 10
250
15 – 20
280
25 – 30
320
40 – 50
360
60 – 75
400
100 – 125
440
Commercial pumps Series 4300, 4360 and 4380
Vertical In–Line pumps
1200 rpm
tefc
dB-A
hp
dB–A
0.75 – 1
59
58
1.5 – 2
61
61
3 – 5
66
65
7.5 – 10
70
69
15 – 20
75
74
25 – 30
77
77
40 – 50
80
80
60 – 75
100 – 125
82
84
100 – 125
150 – 200
85
88

1.1 instructions for safe use

No installation of this equipment should take place
unless this document has been studied and under-
stood. Handling, transportation and installation of
this equipment should only be undertaken by trained personnel
with proper use of lifting equipment. See later diagrams for lift-
ing advice. Refer to the pump nameplate for pump speed, pres-
sure and temperature limitations. The limits stated must not be
exceeded without written permission from Armstrong .
1. 2 temper ature
Where under normal operating conditions the limit of
68°c/155°f (restricted zone) for normal touch, or 80°c/176°f
(unrestricted zone) for unintentional touch, may be experi-
enced, steps should be taken to minimize contact or warn
operators/users that normal operating conditions will be
exceeded. In certain cases where the temperature of the
pumped liquid exceeds the above stated temperature levels,
pump casing temperatures may exceed 100°c/212°f and not
withstanding pump insulation techniques appropriate mea-
sures must be taken to minimize risk for operating personnel.

1.3 noise levels

Typical Pumping Unit Sound Pressure Level, Decibels,
A-Weighted, at 1 m (3 ft.) from unit.
1800 rpm
odp
tefc
hp
dB–A
hp
1 – 3
1 – 2
64
3 – 5
3 – 5
66
7.5 – 10
7.5 – 10
70
15 – 20
15 – 20
74
25 – 30
25 – 30
74
40 – 50
40 – 50
78
60 – 75
60 – 75
80
83
100
125 – 150
87
3600 rpm
odp
dB–A
hp
dB–A
1.5 – 3
64
70
5 – 7.5
68
74
10 – 15
73
76
20 – 25
78
78
30 – 40
82
80
50 – 60
83
83
75 – 100
89
88
125 – 150
92
92
200 – 250
95
125 – 150
96
tefc
hp
dB–A
1.5 – 2
79
3 – 5
82
7.5 – 10
85
15 – 20
88
25 – 30
89
40 – 50
94
60 – 75
95
100
96
98