DIS Sensors QG40N 사용자 설명서 - 페이지 3
{카테고리_이름} DIS Sensors QG40N에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DIS Sensors QG40N 5 페이지. Tilt/acceleration switch (sil1 plc)
DIS Sensors QG40N에 대해서도 마찬가지입니다: 사용자 및 안전 매뉴얼 (6 페이지), 사용자 설명서 (15 페이지)
QG40N Tilt SIL1 PLc
User Manual DIS-sensor
Safety level
4
SIL safety level: SIL CL1 (claim limit 1 according to IEC 62061)
PL safety level: PLc (according to EN ISO 13849)
Architecture: HFT=0 (according to IEC 62061) & CAT2 (according to EN ISO 13849)
This is a self-certified safety device
The firmware of this device is developed according to EN ISO 13849 and meets the SRESW requirements for both 'PL a to
d' and 'PL c or d'
See separate 'Declaration of Conformity' for all safety related parameters
Tilt switch sensor explained
5
An inclinometer measures the angle(s) of the device with respect to earth gravity, using earth gravity vector as external
reference. The inclinometer involved is based on an accelerometer. The acceleration values are used to calculate the angle(s).
The device takes both the static component (100%) and the dynamic component (partial, depending on frequency and
bandwidth-setting) into account.
The Tilt switch sensor realises the switching behaviour for the NPN/PNP outputs based on these inclinometer angles by the
internal microcontroller.
Safety function
6
The safety function of the Tilt switch sensor is to generate the requested switching behaviour based on acceleration values
(caused by gravitation) measured by a MEMS acceleration sensor chip. Based on this switching behaviour the safety
controller of the application can switch the machine to safe-mode in order to prevent for a dangerous situation.
Example: a crane-arm having a maximum tilt angle w.r.t. the chassis. If the tilt angle of the crane-am exceeds a certain
critical value, it can become dangerous. To prevent for this a Tilt switch can be mounted on the crane arm, measuring angle
of the crane arm. The safety controller of the application should monitor the Tilt switch outputs and should switch the crane
to safe-mode as soon as one of the Tilt switch outputs become non-conducting. This will significantly reduce the risk of a
dangerous situation to happen.
Hardware setup
7
Connection:
Default:
5-pins M12 connector male (A-coding). See datasheets for details
Optional:
Cable with open ended wires. See datasheets for details
EMC / CE
8
See separate 'Declaration of Conformity'
V1.2
3
page 3 of 5