Armstrong FLO-RITE-TEMP 535 설치 및 조정 지침 - 페이지 16

{카테고리_이름} Armstrong FLO-RITE-TEMP 535에 대한 설치 및 조정 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Armstrong FLO-RITE-TEMP 535 20 페이지. Instantaneous water heater. instructions for single and double wall units
Armstrong FLO-RITE-TEMP 535에 대해서도 마찬가지입니다: 설치 및 조정 지침 (17 페이지)

Armstrong FLO-RITE-TEMP 535 설치 및 조정 지침
Clean-In-Place Operating Instructions
When there is a noticeable drop in the Flo-Rite-
Temp's — hot water capacity, temperature, or an increased
water pressure drop across the unit — tube bundle scale
removal should be considered using the commercially
available product called RITE-Qwik*.
Tube bundle scale removal can be accomplished as
follows:
Step 1 - Shut off steam supply valve #1 to the Flo-Rite-
Temp.
Step 2 - While the water pressure is still ON and the steam is
OFF, run the Flo-Rite-Temp for (10) ten minutes or until the
outside of the unit is cool to the touch.
Step 3 - Shut the water inlet valve #4 OFF and water outlet
valve #5 OFF; open cleaning connection outlet #7. Connect
air hose with regulator to valve #9. Turn air on slowly to
approximately 5 psi. Increase to maximum of 25 psi. Leave
air pressure on until water stops coming out of connection
#7. Turn air (valve #9) off. Open cleaning connection inlet #8
and remove the pop-off valve or inlet pipe plug #6 from the
lower diaphragm cover of the control valve . Let the
remaining water drain by gravity from the Flo-Rite-Temp.
Step 4 - After all the water has been drained, reinstall the
pop-off valve or pipe plug #6 into the lower diaphragm cover
of the control valve.
Step 5 - With hose valve closed connect return hose A of the
Clean-in-Place to the outlet cleaning connection #7 of the
Flo-Rite-Temp.
Step 6 - With hose valve closed connect discharge hose B of
the Clean-in-Place to the inlet cleaning connection #8 of the
Flo-Rite-Temp.
Step 7 - Start pump. Open ball valve of discharge hose B of
the Clean-in-Place.
Step 8 - Slowly open the ball valve on return hose A and
watch for foaming in the tank.
Step 9 - Clean-in-Place is now circulating cleaning solution
through the Flo-Rite-Temp. Periodically check the solution
to see if it has changed color or quit fizzing. If the cleaning
Flo-Rite-Temp
2
5
3
4
7
* RITE-QWIK is a non hazardous chemical cleaner which has been proven effective for removing deposits without
harming the FLO-RITE-TEMP internally.
1
6
9
Air
8
solution has stopped fizzing and has not changed color, the Flo-
Rite-Temp is clean. You may save the remaining unspent solution
for your next job. If the solution quits fizzing and the color has
changed, add new cleaning solution. Continue circulating in the
same manner as above. Do not exceed a maximum
circulation time of (3) three hours.
Step 10 - Shut-off pump. Close discharge hose valve B on
Clean-in-Place. Open air (valve #9). Turn air on slowly to
approximately 5 psi. Increase as Clean-in-Place fluid returns to
tank. (Maximum air pressure 25 psi.)
Step 11 - Leave air blow for approximately 3-5 minutes. This
should return most of the fluid to the tank. Close both hose
valves.
Step 12 - Disconnect return hose A from the Flo-Rite-Temp outlet
cleaning connection #7 and discharge hose B from the inlet
cleaning connection #8. Also remove the pop-off valve or pipe
plug #6 from the lower diaphragm cover of the control valve. Let
the cleaning solution drain by gravity from the Flo-Rite-Temp.
Step 13 - Close valve #2 going into the system and open valve
#3 going to the drain.
Step 14 - Open the water outlet valve #5 then open SLOWLY
inlet water valve #4. Let the water run for (1) one minute before
installing the pop-off valve or pipe plug #6 into the lower
diaphragm cover of the control valve.
Step 15 - After the pop-off valve or pipe plug #6 is installed, run
water into the drain for (5) five minutes to flush out all of the
cleaning solution. Throttle the outlet valve #3 open and closed to
purge the air from under the diaphragm.
Step 16 - After flushing the unit, close valve #3 and open the
steam supply valve #1 SLOWLY and let the Flo-Rite-Temp heat
up.
Step 17 - Set the Flo-Rite-Temp as needed. (This step may not
be necessary).
Step 18 - Open valve #2 to the system and monitor the system
until the temperature is back to normal.
Step 19 - After use, flush the pump with water to remove the
chemical to prevent seal deterioration.
Clean-In-Place
Return
Hose
Discharge
Hose
16
35"
(889 mm)
Air Vent
47"
(1194 mm)
Drain