Acorn Safety S0000-AL3 설치, 작동 및 유지보수 지침 - 페이지 6

{카테고리_이름} Acorn Safety S0000-AL3에 대한 설치, 작동 및 유지보수 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Acorn Safety S0000-AL3 9 페이지.

Installation & Operation Manual
WARNINGS:
DO NOT connect AC power to the alarm until
l
directed to in these installation instructions to
reduce the risk of shock.
DO NOT tamper with this device when the
l
signal circuit is energized. Disconnect power
and wait at least 5 minutes for stored energy to
dissipate before handling to reduce the risk of
shock.

SUPPLIES REQUIRED:

(not provided by Acorn)
1. UL building wire to make connections from flow
switch, alarm (light / horn) and electrical service.
2. Piping, unions or other connections to meet
required minimum distances for flow switch.
3. 4" x 4" x 2-1/8" J-box and 1-1/2" J-box
extension for adapting alarm for flush mounting
to finished wall.
4. Surface mounting may require wall anchors and
anchoring hardware for wall mounting alarm
box.
5. Pipe sealant or Teflon tape for sealing water
connections.
IMPORTANT: FLUSH WATER SUPPLY LINES
PRIOR TO CONNECTION TO SAFETY
EQUIPMENT.
Notes:
Flow Switch must be installed with tee fitting in
l
horizontal position, switch body in vertical
position (as shown on page 3) and at least 6"
from closest fitting.
Flow Switch direction of flow is indicated on
l
switch body.
Use hand tools and wrenches in a manner
l
which will prevent marring finished surfaces.
Strap wrenches or tools with plastic jaw linings
are highly recommended.
Refer to fixture rough-in information for location
l
of supply lines.
Fragments of Teflon tape or pipe sealant residue
l
can interfere with the proper operation of this
unit. Ensure pipe sealant methods do not cause
contamination in the system.
Acorn Safety
a division of Acorn Engineering
Manual #7109-305-001
S0000-AL3
FLOW SWITCH
JUNCTION COVER
FLOW SWITCH
BODY
1-1/4" NPT TEE
CONNECTIONS
DIRECTION OF FLOW
INDICATOR IS NOT
EASY TO SEE
S0000-AL3-FLW2
FLOW SWITCH
JUNCTION COVER
FLOW SWITCH
BODY
½" NPT TEE
CONNECTIONS
DIRECTION OF FLOW
INDICATOR IS NOT
EASY TO SEE
Page 6 of 9
3
" NPT FOR CONDUIT
4
BY OTHERS
1-1/4" NPT x 1" NPT
ADAPTERS PROVIDED
3
" NPT FOR CONDUIT
4
BY OTHERS
1
3
" NPT x
" NPT
2
8
ADAPTERS PROVIDED
Revised: 12/10/18