TROUBLESHOOTING
Poor Fountain performance
•
Reduced height.
•
Jets blocked.
Clean flow adjusters and fountain
head. Wash under a tap or hose.
Pond Pump Cleaner should be used
to remove lime scale build-up/waste
(see diagram) for improved results.
No flow from pump
1. Check power supply is on.
2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION).
3. Follow low flow procedure as above.
If none of the above works contact Interpet (Blagdon) Consumer Advice Department
(See Faults problem procedure Page 25).
Green water
•
Settlement test the water to ensure that there is no sediment suspended in the water. If
there is, follow the brown cloudy water troubleshooting guide.
•
In order to check that the UVC lamp is operating: Open the filter unit (see page 15)
remove the filter foams and cartridge. Positioned on top of the yellow UVC contact
chamber will be a round viewing window where you should see a faint blue light.
This operation may need to be carried out at dusk as UVC lamps emit a dim blue light
under normal operation. Turning the lamp on and off may aid visual identification.
(Ensure the UVC lamp is not more than 6 months old).
•
The UVC may be working effectively but the filter foam/media is too clean and is
unable to remove the fine coagulated waste. Treat the pond with Clear Pond and do
not clean the foams/media until they are blocked.
•
The filter is too small for the pond, check your filter selection chart.
•
The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the quartz sleeve
and clean.
•
Follow all cloudy water trouble shooting points.
26
DAISY
To clean, remove head
and rinse.
Or in hard water
areas, use Pond Pump Cleaner
TROUBLESHOOTING & IMPORTANT
UVC light not illuminated
•
Check all fuses / RCD and electrical connections follow electrical installation
Faults - Problem Procedure
Before returning your Inpond to your dealer or contacting our Consumer Advice
Department, please carry out the following steps. This will solve most problems quickly
and easily.
1. Ensure electrical procedures have been followed fully. Check fuses and any cable
connectors/switch boxes.
2. (a) Follow routine maintenance procedure fully. (b) Check location and connecting your
pump details including flow rates. (c) Ensure that your pond volume and pump flow rate
meet the maximum pond size recommended for the filter model on the filter
performance and specification chart. (d) Follow troubleshooting guide.
3. If there is a mechanical breakdown of the filter or UVC, return to the point of purchase
for inspection and advice (You will need proof of purchase).
Guarantee
UV & FILTER
This product is guaranteed against defects in material and workmanship for 3 years from the
date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper
use, negligence, lack of maintenace or accidental damage to either the filter or UVC. If the
filter or UVC fails due to a manufacturing fault within this period it will be either repaired or
replaced free of charge. Liability is limited to replacement of the faulty product only; no other
costs will be reimbursed. The guarantee is not transferable and does not affect your statutory
rights. This guarantee does not confer any rights other than those expressly set out above. This
guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn
or every 6 months. If any parts are needed, spares are availible from your retailer.
27