DISCOVER 14-48-3000 운영 매뉴얼 - 페이지 10

{카테고리_이름} DISCOVER 14-48-3000에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DISCOVER 14-48-3000 16 페이지. Lithium ion battery

Model
14-12-3000
14-24-3000
14-36-3000
14-48-3000

7.4 Discharging

• Set the battery to ON
• Set the load to ON
• Recommended low voltage cut off: 12 V | 24 V | 36 V | 48 V

7.5 Storage

Systems should be turned off and stored out of direct sunlight in compliance with the following temperature conditions:
Batteries should never be stored at 100% SOC. Store batteries at approximately 80% SOC and checked monthly to ensure the
SOC does not fall below 20%. At 20% SOC the battery will self discharge in approximately 2 months.
8. Service & Maintenance

8.1 Warranty Registration

To register your product you will need the serial number of the battery. Visit discoverbattery.com for registration details.

8.2 Inspection

Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm.
This routine should be started when the batteries are first received.
• Inspect for cracks in the battery casing
• Check battery terminals and connections to make sure they are clean, free of dirt, fluids and corrosion
10
▲ CAUTION!
Do not charge battery higher than 3.4 V per cell module.
▲ NOTE!
Recommended charge current is 0.5C
Cell Modules
Bulk Current
in Series
4 S
150 Adc maximum
8 S
114 Adc maximum
12 S
76 Adc maximum
16 S
57 Adc maximum
▲ NOTE!
Do not discharge battery below the recommended
minimum operating voltages.
▲ NOTE!
Do not discharge battery at rates greater than
recommended operating currents.
Recommended Minimum
Recommended Maximum
▲ CAUTION!
Do not store a discharged battery. Recharge battery after every
use. Batteries that have self-discharged to a severely discharge
state are not recoverable.
Absorption
Termination
Voltage
Charge Current
13.6 V
27.2 V
I2 ≤ 2 A
40.8 V
54.4 V
-10°C / 14°F
30°C / 86°F
discoverbattery.com