DISCOVER 15-24-1000 운영 매뉴얼 - 페이지 4

{카테고리_이름} DISCOVER 15-24-1000에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DISCOVER 15-24-1000 11 페이지. Lithium ion battery

3. Design Features & Components
3.1 Battery Management System (BMS)
Monitoring
BMS monitors:
Cell module voltage
Battery voltage
Battery current
Battery temperature
Battery state of charge (SOC)
Module Balancing
BMS performs balancing of cell modules.
Protection & Fault Management
BMS sounds buzzer when fault limits are reached
BMS generates fault when maximum operating limits are reached
Fault events cause switch to open and battery to shut down after a 120s delay
Communication Ports
BMS has an isolated RS232 communication port (for service technician use only).
3.2 Fuse
Fuse provides back-up over-current protection.
Fuse Replacement
A blown fuse requires service from a qualified technician. Contact your Discover supplier for more information.
3.3 Terminals
Terminals are post-type, M6 female.
4. Handling
• Battery should be off
• Battery cables should be disconnected
• Battery terminals should be protected
• Battery handle should be used to lift battery
• Do not lift or carry the battery during usage or operation
5. Installation - Single Battery
▲ CAUTION!
Do not install batteries in series. Select the appropriate
AES battery model for the voltage of your system.
▲ NOTE!
Intentional bypassing of BMS to operate battery outside
maximum and minimum limits voids warranty.
Terminal Torque
▲ WARNING!
Read Safety Section before installing the battery.
▲ WARNING!
Read Safety Section before installing the battery.
7.0-7.7 Nm / 5.1-5.7 Ft-lb
4