{카테고리_이름} DISCOVER DRY CELL에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DISCOVER DRY CELL 11 페이지. Valve regulated lead acid battery
indicate a cell failure or short. Verify the voltage readings from each battery, and perform a load test to identity any cell failures.
WHAT DO I DO IF THE BATTERY IS FROZEN?
Discover Dry Cell batteries can be stored in sub-freezing temperatures as low as 35 °C / -31°F as long as they are fully charged prior
to storage. The self-discharge rate of fully-charged batteries is very low in these conditions and they will not require charging for
many months. However, if your batteries do freeze, they may not always recover. To attempt recovery bring them inside and let them
sit until the temperature of the battery reaches the temperature of the room, approx. 20°C / 68°F , then charge the batteries normally.
You may have to cycle the battery a couple of times before making a decision on its final condition.