3. Set the following parameters for Discover Lithium batteries:
• Battery Type: Lithium-ion (Li-Ion)
• Nominal capacity of the battery: Installed number of batteries x their nominal
capacity in Ah
SUNNY ISLAND 6.0H
Home
1
2
Battery configuration
Type
Lithium-ion (Li-ion)
Back
• Nominal voltage for the battery is automatically set to 48 V.
• Only mandatory values for the basic operation of the Sunny Island system are
available for set up in the QCG.
7.4 LYNK II and Sunny Island Communication
The LYNK II Communication Gateway provides power conversion and monitoring
devices with BMS real-time data in a closed-loop configuration to optimize control
over the charging process in solar applications. LYNK II also enables the remote
monitoring of Discover Lithium battery SOC and data logging of multiple sites using
the data monitoring services offered by off-grid inverter systems.
If communication is interrupted between the LYNK II and power conversion device,
after about 1 minute the power conversion device throws a fault (952).
Once communication is re-established, the operations of the power conversion
device and the LYNK II communication gateway resume.
3
Minimum capacity
1000
Ah
Figure 8. Battery Configuration in WebConnect