DISCOVER LITHIUM BLUE DLB-GC12-24V 고객 서비스 게시판 - 페이지 2
{카테고리_이름} DISCOVER LITHIUM BLUE DLB-GC12-24V에 대한 고객 서비스 게시판을 온라인으로 검색하거나 PDF를 다운로드하세요. DISCOVER LITHIUM BLUE DLB-GC12-24V 2 페이지.
•
To identify charge circuit damage, the battery terminal voltage jumps up to the charge voltage while the app shows
no current and a much lower voltage, the exact discrepancy depends on the actual block voltage.
•
It is normal to have a small discrepancy between terminal and battery voltage shown in app during normal
operations.
SoC is inaccurate:
Lithium batteries have a flat discharge curve making it necessary to estimate SoC based on an algorithm considering
numerous present data points and historical usage factors. Low currents and usage. parasitic draws, may result in an
inaccurate SoC calculation.
•
To reset the SoC calibration please refer to CSB 855-0014 Lithium BLUE – SOC Calibration
https://assets.discoverbattery.com/documents/dl_blue/csb-dlb-soc-calibration.pdf.
•
Customers with multiple batteries may benefit from using an external SoC gauge (such as Victron).
Battery Voltage
12V
24V
36V
Positive terminal deformation / melting of cover
Refer to CSB 855-0012 DLB 12V Positive Terminal Overheating
https://assets.discoverbattery.com/documents/dl_blue/csb-dlb-12v-positive-terminal-overheating.pdf.
For other issues or additional support, please submit a support request at:
https://discoverbattery.com/contact/contact-support.
CUSTOMER SERVICE BULLETIN
Reference SoC Voltages
0% SoC
20% SoC
80% SoC
12.0V
~12.8V
~13.3V
24.0V
~25.6V
~26.6V
36.0V
~38.4V
~39.9V
- End of Document -
100% SoC
>=13.6V
>=27.2V
>=40.8V
Page 2 of 2
F orm: 880-0012 Rev A