ARO 662609 운영자 매뉴얼 - 페이지 4
{카테고리_이름} ARO 662609에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ARO 662609 4 페이지. Ingersoll-rand water pump user manual
No material at outlet. (Pump continuously cycles).
Empty material supply. Disconnect the air, replenish the
material supply.
Foreign matter is holding foot valve seats open in lower
pump tube assembly. Remove lower pump tube assem-
bly and clean valve seats.
Pump operates sluggishly, tends to stick when air is
applied or control is opened.
Air motor is dirty or lacks lubrication. Clean air motor.
Insuffi cient air pressure or volume of air. Check air supply.
Page 4 of 4
TROUBLE SHOOTING
Air bypasses through exhaust port.
Foreign matter is holding air valve open or lacks lubrica-
tion. Consult factory for nearest Service Center.
Motor stalls.
Foreign matter in pump, hose, control valve or spray tip
obstructing material flow. Check material supply hose
and control valve or tip.
Air not getting to pump. Check air supply.
PN 97999-75
66260X