GENERAL DESCRIPTION
The ARO diaphragm pump offers high volume delivery even
at low air pressure and a broad range of material compatibili-
ty options are available. Refer to the model and option chart.
ARO pumps feature stall resistant design, modular air motor /
fluid sections.
Air operated double diaphragm pumps utilize a pressure dif-
ferential in the air chambers to alternately create suction and
a positive fluid pressure in the fluid chambers, valve checks
insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and will
continue to pump and keep up with the demand. It will build
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and
will resume pumping as needed.
AIR AND LUBE REQUIREMENTS
EXCESSIVE AIR PRESSURE. Can cause pump
WARNING
damage, personal injury or property damage.
A filter capable of filtering out particles larger than 50
y
microns should be used on the air supply. There is no lu-
brication required other than the "O" ring lubricant which
is applied during assembly or repair.
If lubricated air is present, make sure that it is compatible
y
with the "O" rings and seals in the air motor section of the
pump.
OPERATING INSTRUCTIONS
Always flush the pump with a solvent compatible with
y
the material being pumped if the material being pumped
is subject to "setting up" when not in use for a period of
time.
Disconnect the air supply from the pump if it is to be in-
y
active for a few hours.
The outlet material volume is governed not only by the air
y
supply, but also by the material supply available at the in-
let. The material supply tubing should not be too small or
restrictive. Be sure not to use hose which might collapse.
When the diaphragm pump is used in a forced-feed
y
(flooded inlet) situation, it is recommended that a "check
valve" be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to
y
insure against damage by vibration.
y Hytrel®, and Viton® are registered trademarks of the DuPont Company y Loctite® is a registered trademark of Henkel Loctite Corporation y Kynar® is a registered trademark of Arkema Inc. y
y Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. y ARO® is a registered trademark of Ingersoll-Rand Company y
y Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) y 262™, 271™ and 572™ are trademarks of Henkel Loctite Corporation y
Page 4 of 12
PARTS AND SERVICE KITS
Refer to the part views and descriptions as provided on pages
5 through 8 for parts identification and service kit informa-
tion.
Certain ARO "Smart Parts" are indicated which should be
y
available for fast repair and reduction of down time.
Service kits are divided to service two separate diaphragm
y
pump functions: 1. AIR SECTION, 2. FLUID SECTION. The
Fluid Section is divided further to match typical part Ma-
terial Options.
MAINTENANCE
Provide a clean work surface to protect sensitive internal
y
moving parts from contamination from dirt and foreign
matter during service disassembly and reassembly.
Keep good records of service activity and include the
y
pump in preventive maintenance program.
Before disassembling, empty captured material in the
y
outlet manifold by turning the pump upside down to
drain material from the pump.
FLUID SECTION DISASSEMBLY
1. Remove (61) outlet manifold and (60) inlet manifold.
2. Remove (22) balls, (19) "O" rings (if applicable) and (21)
seats.
3. Remove (15) fluid caps.
NOTE: Only PTFE diaphragm models use a primary dia-
phragm (7) and a backup diaphragm (8). Refer to the auxiliary
view in the Fluid Section illustration.
4. Remove the (6) diaphragm washer, (7) or 7 / 8) dia-
phragms and (5) backup washer.
NOTE: Do not scratch or mar the surface of (1) diaphragm
rod.
FLUID SECTION REASSEMBLY
SERVICE NOTE: ARO pn 204214-T diaphragm assembly tool
is recommended for use when reassembling the pump.
Reassemble in reverse order. Refer to the torque require-
y
ments on page 6.
Clean and inspect all parts. Replace worn or damaged
y
parts with new parts as required.
Lubricate (1) diaphragm rod and (144) "U" cups with Lubri-
y
plate® FML-2 grease (94276 grease packet is included in
service kit).
For models with PTFE diaphragms: Item (8) Santoprene
y
diaphragm is installed with the side marked "AIR SIDE"
towards the pump center body. Install the (7) PTFE dia-
phragm with the side marked "FLUID SIDE" towards the
(15) fluid cap.
Re-check torque settings after the pump has been
y
re-started and run a while.
PX20X-XXX-XXX-BXXX (en)