I. Mount the Bracket to the diaphragm pump:
1.
Attach the front bracket to the top manifold of the pump,
making sure the vertical edge of the bracket is against the
flat side of the manifold (where ARO logo is). See Figure 2.
NOTICE
This applies to manifolds with round cross section, like PRO
and EXP plastic pumps.
2.
Mount the rear bracket from the opposite side of the mani-
fold and secure in place with the M8 bolts and nuts. See
Figure 3.
NOTICE
Use the long bolts (70mm) for the 3" pumps and the 2" plas-
tic EXP pump. Use the short bolts (30mm) for the 2" metallic
pumps.
3.
Tighten the bolts/nuts, making sure the distances between
the front and rear brackets are equal at all four bolt loca-
tions.
NOTICE
Make sure the bracket is fixed in place and it will not move.
Figure 2
Figure 3
Page 2 of 8

INSTALLATION

II. Mount the LLS to the bracket:
Mount the LLS to the bracket using the M6 bolts and the
washers. See Figure 4.
Tighten all bolts and make sure the LLS is fixed in place and
it will not move.
Front Bracket
III. Mount the PCV Module to the air inlet of the diaphragm
pump:
1.
The PCV Module should be assembled.
2.
Mount the union to the air inlet of the diaphragm pump.
3.
Mount the PCV Module to the union, see Figure 5.
Wrap the male thread with the thread seal tape before in-
stallation.
PCV
Module Union
Rear Bracket
Pump Air Inlet
NOTICE
Liquid Level
Sensor (LLS)
Figure 4
NOTICE
Figure 5
SCD501BN08-VXX (en)