disguise gx 1 하드웨어 매뉴얼 - 페이지 10
{카테고리_이름} disguise gx 1에 대한 하드웨어 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. disguise gx 1 17 페이지.
Powering your server
The pro and gx range uses the Neutrik powerCON TRUE1 as its power input. This mains connector is:
• Lockable
• Live-Mating (safely)
• Extendable
• Dust and water resistant
To power the server you should use a cable with the following attributes:
• SJT flexible cord, min. 12AWG, min. 300V, min. 60
• One end terminated with NEMA 5-15P/BS 1363/CEE 7/7 plug
• Other end terminated with appliance coupler type Neutrik NAC3FX
Powering a Multi Server System
The pro and gx range servers (apart from the vx 4) feature a power pass-through, making it possible to connect multiple
systems.
The power input to the machine is rated at 12Amps RMS per connection in Europe and USA.
Loop through cables should have the following attributes:
• SJT flexible cord, min. 12AWG, min. 300V, min. 60ºC, max 4.5m long
• One end terminated with appliance coupler type Neutrik NAC3MX-W
• Other end terminated with appliance coupler type Neutrik NAC3FX
Left - True1 Powercon and Loop Through connections on rear of unit.
Right - Vx 4 Power panel with Tue1 Input.
pro & gx Hardware Guide | Q1 2019
º
C, max 4.5 m long
Power cable daisy chain
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
[email protected] | www.disguise.one | 9