AERF MONO 1H 지침 - 페이지 2

{카테고리_이름} AERF MONO 1H에 대한 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. AERF MONO 1H 4 페이지.

GB
4. TIME REGULATIONS
AUTOMATIC CLOSING TIME
Regulates the waiting time before the automatic close
Turn LEFT to decrease and RIGHT to increase
-
+
Minimum - 5 sec
Maximum - 90 secs
4. OPTIONS
1
AUTOMATIC
CLOSING
2
DISABLE STOP
ON OPENING
3
PHOTOCELL 2 /
SAFETY EDGE
4
RADIO FREQUENCY
PROGRAMMING
5
DEAD MAN
(see point 6.)
6. DEADMAN
Dead man working conditions (Option 5 ON )
I5 = ON, In this case there will be no safety on automatic opening.
An open (N.O.) switch should be connected between CSEG1 & common CSEG which will serve as a closing switch.
I3 = ON Dead man will be activated on opening and closing.
I3 = Off Dead man will be activated only on closing.
7. PHOTOCELL TEST
At the beginning and end of each door operation the control panel tests the state of the photocells.
Once connected, the test function tests the cells 5 times (these 5 tests must be successful) to verify and memorize the connection. The
control panel independently tests the two photocell inputs (CSEG & CSEG1). EG: We could have a photocell with test in input CSEG & bridge
CSEG1. The control panel knows that there is a photocell with test CSEG and one without test on CSEG1. If a photocell connected to the test
does not pass or fails, a RED LED FLASHES (programme indicator led), thus no automatic function will be allowed until a successful test has
MONO 1H
ON
- Door closes automatically after waiting a.c. time.
1
2
3
4
5
ON
- Door does not close automatically.
1
2
3
4
5
ON
- On opening the alternative button (15-16) is disabled.
1
2
3
4
5
ON
- On opening, if alternative button (15-16) is pressed, door stops.
1
2
3
4
5
- Input (12-13) works like 8k2 safety edge, stopping & reversing the maneuver in the
ON
opening and closing.
1
2
3
4
5
- Input (12-13) works like safety photocell, stopping the maneuver in the opening.
ON
1
2
3
4
5
ON
- Allowed.
1
2
3
4
5
ON
- Not allowed.
1
2
3
4
5
ON
- DeadMan functionality enabled.
1
2
3
4
5
ON
- DeadMan funcitonality disabled.
1
3
4
2
5
WORKING TIME
Regulates the opening and closing time
Turn LEFT to decrease and RIGHT to increase
-
+
Minimum - 3 sec
Maximum - 90 secs
2 - 4