dimension & installation guide
freestanding dishwasher - DX103
IMPORTANT
• These instructions are a guide only. For complete
installation instructions, refer to the manual provided with
the product.
• If you do not follow the installation instructions your
dishwasher will not be properly installed. The product
warranty does not cover incomplete or improper
installation. You will be charged a service fee for any service
call to rectify improper or incomplete installation.
Dishwasher Dimensions
The dimensions shown below are in millimetres.
The height shown is with the levelling feet screwed
in all the way.
100mm
595mm
Typical builT-unDer insTallaTion
There should be a minimum
2mm gap between the top of
the dishwasher and
underside of bench top
Please note: if you remove the benchtop to
build-under the dishwasher, no brackets or
screws are provided. These will need to be
purchased from spare parts.
DISHWASHER
Gap on both sides
should be equal and no greater
than 3mm maximum per side
If floor is not level, adjust
levelling legs to suit
820mm
(850mm
with worktop)
180mm
50mm
575mm
(610mm
with worktop)
The hose should not be
extended by more than
2 metres or water pump-out
problems may occur
600mm max -
300mm min
cupboarD opening Dimensions
The dimensions shown below are in millimetres. The opening
allows for some clearance so that the dishwasher can be
pushed into place.
Note: if the opening is greater than 600mm wide then a suitable
width filler piece should be secured to the cupboard before
installing the dishwasher.
Fix drain hose max of
10mm below the top of
the dishwasher
SINK
1000mm max
POWER OUTLET
POWER SUPPLY
230/240V–10Amps
Remove entire plastic
membrane from sink trap
spigot & fit drain hose to
spigot with clamp
TAP CONNECTION
If cold-water pressure is
in excess of 800kPa, a
pressure-reducing valve
should be used.
Check for leaks.
INLET WATER SUPPLY
Water flow rate 10L/minute min
Water temperature 60°C max
Water pressure cold water:
800kPa max - 50kPa min
Water pressure hot water:
350kPa max - 50kPa min
Cold water recommended
(Refer page 3 for further information)