CX-WC17VR-PS SERIES RESTROOM KIT
INSTALLATION INSTRUCTIONS
Wall
W av
e S
w itc
In -w
CM-7536VR
D ril
C ut
h w
E le
al l
l a Ø
-o ut
ct ric
Hands-Free
ire
CM-7536VR
al B
0. 25
Column™
0' ' H
Hands-Free
ox
ol e
switch
Column™
switch
2 1/
[6 4.
2''
77 m
m ]
Mounting without in-wall
Mounting with in-wall
electrical box
electrical box
Figure 3.3 Wall Mounting Options
4. Using a level tool, ensure the base unit is perfectly levelled and mark 4
PROPRIETARY AND CONFIDENTIAL
A.OLISA
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
mounting locations through the adjustable nylon inset screws onto the
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
wall surface (if mounting on drywall, use a pencil, and if mounting on
concrete wall, use a narrow sharp object for marking).
5. Drill the wall at the four marked locations and tap in the appropriate
wall plugs. We supply both drywall and concrete anchors for the
included #14 screws.
6. If mounting the Column Switch on an aluminium post or framing
section, drill and tap four holes for 1/4"-20 stainless steel machine
screws (also provided).
7. Connect all the wires coming from the CX-33PS box to the CM-221
sensor.
8. Secure the assembly with the provided mounting screw, and insert
actuation bar which was removed in step 1, and finally secure it with
End cap.
T o p
C a p
In s e
r t
S c r
e w s
2 1 /2
[6 2 .0
''
m m
]
W a
ll A n
c h o
r s
8
6
5
7
M o u
n ti n
S c r
g
3 6 ''
[9 1 4
e w
.3 m
m ]
End Cap
B a s
D
e U
n it
A c u
a to r
Hanger
3 6 ''
C
[9 1 4
.3 m
m ]
Slot
F lo o
r
2 1 /1
[5 2 .1
6 ''
m m
]
Figure 3.3 Mounting of Base Unit
B
PROPRIETARY AND CONFIDENTIAL
Page 3 of 9
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CAMDEN DOOR CONTROLS. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF CAMDEN DOOR
CONTROLS IS PROHIBITED.
CONNECTIONS
Wall
IMPORTANT: Do not apply power to the unit until you
have fully read the instructions and have made the
required adjustments.
The CX-WC17VR-PS Restroom Control Kit comes with the CX-33PS: Advanced
Logic Relay, Power Supply and Cabinet, which has a set of two terminal strips.
Each strip has a clear label for wiring, and it is also pre-wired, which eliminates
the need for a separate wiring manual for the termination point. However, later
sections of this manual include detailed wiring diagrams for reference.
The left-side terminal strip is used to power CX-33PS, the PUSH to OPEN (both
5502 Timberlea Blvd.
exterior and interior) column switches, PUSH to LOCK column switch, the door
Mississauga, ON Canada
L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
position switch, and the wet trigger. The right switch of the terminal is used to
24/03/22
power the outputs to drive the strike (Relay 1), door operator (Relay 2), LED
CUST
light (Relay 3), and provide VDC power for the door strike.
There are six wires from CM-221 needs to be connected with terminal strips:
Table 3.1 Wiring Description for CM221
Wire Color (from
Splicing With
CM-221)
Red wire
-
Black wire
-
Yellow wire
-
White wire
-
Green Wire
Top Switch wire
Blue Wire
Top Switch wire
IMPORTANT:
The supplied CX-TRX-5024 transformer will have its secondary terminals
wired to the terminals on the top of the left terminal strip marked as "AC".
4
3
2
1
Next, wire the primary terminals to the AC feed to be used. Confirm your
connections and apply power by turning on the electrical panel breaker.
End Cap
Hanger
Note:
While placing actuation bar back, make
sure that hanger sits perfectly into the slot.
Slot
5502 Timberlea Blvd.
Mississauga, ON Canada
L4W 2T7
Tel: (905) 366-3377
www.camdencontrols.com
Angelo
08/12/22
CM-753VR Column Switch
4. Installation
1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws
and pressed metal nuts. Do not tighten.
4. CX-ED2079 'universal' electric strike installation
1. Firstly, verify that voltage required to operate Electric strike is compati-
faceplate into jamb. Add one of more spacers between
ble with supply voltage of the installation.
jamb and mounting bracket when face plate extends
POWER: Red/Black, Blue/Green (12 VDC)
beyond the jamb. When the faceplate sits inside the
Red, Black/Blue, Green (24 VDC)
jamb, spacers must be added between the mounting
Red/Green (Sort Black, Blue)
bracket & the lip bracket. Make sure clearance hole in
2. Splice the strike wire with the supplied wire and make sure to attach
spacer aligns with hole in mounting bracket.
provided varistor as described in connection section.
Mounting Bracket
Spacer
To (CX-33PS)
+V DC
-V DC
Green LED
Red LED
Inside/Outside Push
to Open and Push
to Lock
Figure 4.1 CX-ED2079 Strike Mounting
Note: The products are intended to be installed in accordance
with the installation wiring diagram, mechanical assembly
Note:
drawings provided with each product, the local authority having
•
jurisdiction (AHJ) and the National Electric Code, NFPA 70.
The products are intended to be installed in accordance with the
When installed in fail secure mode, the local authority shall be
installation wiring diagram, mechanical assembly drawings provided
consulted with regard to the use of possible panic hardware to
with each product, the local authority having jurisdiction (AHJ) and
D
allow emergency exit from the secure area.
the electric code, NFPA 70. When installed in fail secure mode, the
The electric door strike shall be installed in such a way and
local authority shall be consulted with the regards to the use of
in such a location so as to not impair the operation of an
possible panic hardware to allow emergency exit from the secure
emergency exit device or panic hardware mounted on the door.
area.
•
The electric door strike shall be installed in such a way and in such
C
a location so as to not impair the operation of an emergency exit
device or panic hardware mounted on the door.
B
4. Connect wires coming from the low voltage side of the
transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32
screws and lockwashers.
3. Make sure that the door jamb has an appropriate cutout to accommo-
6. Secure M5x12 screws holding mounting brackets to jamb.
date strike assembly. (Make sure to leave enough room for splicing
between power supply and electric strike wiring.)
4. For a wooden door jamb, drill holes to install the strike and finally use
supplied #12 x 1/2" machine screws to secure the strike.
Spacer
Spacer (Option)
M5x12 Flat-Head Screw (2pcs)
M 5
x 1 2
S c
r e w
p
J a m
Vertical Centerline
CX-WC17VR-PS SERIES RESTROOM KIT
INSTALLATION INSTRUCTIONS
4-7/8"
(124mm)
3-1/2"
(89mm)
3-3/8"
(86mm)
4-1/8"
(105mm)
1-7/32"
(31mm)
ESP1B + ESP2B
6-7/8"
(173mm)
5-11/16"
(144mm)
3-3/8"
(86mm)
6-1/8"
(155mm)
1-7/32"
(31mm)
ESP3B
7-7/8"
(200mm)
6-3/8"
(168mm)
3-3/8"
(86mm)
7-3/8"
(187mm)
1-7/32"
(31mm)
ESP4B
1-3/8"
(36mm)
Figure 4.2 Mounting options for CX-ED2079
Page 4 of 9