CM-324 ACTIVE INFRARED "HANDS-FREE" SWITCH
I NS TA L L AT IO N I NST RUCT I ONS
Diagram 1 - Proper Box Installation
Wall
Correct
Installation
Wall Box
Incorrect Installation
Rough Wall Finish
Recessed Box
2-GANG (or 4x4) ELECTRICAL BOX: CM-324W
1a. If using an in-wall box ensure the box is plumb and square,
and flush with the wall surface (See Diagram 1).
1b. If using a surface box, ensure it is secure & plumb.
1c. If using a 4 x 4 box, ensure the box is plumb and square, and
flush with the wall surface, then attach the metal adaptor
plate (included in the CM-324W package) to the box using
appropriate fasteners.
2. Bring your 4-conductor wire through the back or side of
the enclosure, leaving approximately a 6" tail for
wiring connection.
3. Make the electrical connections to the device according to
the wiring section (following).
4. Using the dip switch located on the end of the unit, set the
operating mode (See Section 4).
5. Attach unit to enclosure using the two #6-32 screws provided.
6. Apply power and adjust range and time delay via
potentiometers on the front of the unit (See Section 4).
7. Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
NOTE: Do not overtighten
Page 2 of 4
Smooth Wall Finish
Flush
Unaligned Box
DOOR FRAME: CM-324N
1a. If mounting directly in a 1" wide aluminum jamb, make a
cutout in the door frame at the intended location as per
Diagram 2.
Drill and tap two mounting holes as shown.
1b. If mounting the unit in CM-23d deep jamb box, first mount
the jamb box according to the instructions packaged with the
enclosure. Using the CM-23D as a guide, drill a wire access
hole through the jamb to fish the wiring through.
2. Bring your 4-conductor wire through the back or side of
the enclosure (or jamb) and leave approximately 6" tail
for wiring connection.
3. Make the electrical connections to the device according
to the wiring section (following).
4. Using the dip switch located on the end of the unit, set the
operating mode. (See Section 4)
5. Attach the unit to the enclosure or jamb using the two
#6-32 screws provided.
6. Apply power and adjust range and time delay via
potentiometers on the front of the unit (See Section 4).
7. Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
NOTE: Do not overtighten
WIRING
CAUTION: Do not apply power to the unit until all secondary
wiring is complete, and dip-switches have been set.
The CM-324 can be powered from 12 or 24 volts, AC or DC.
Connect the two Red wires, (non-polarity sensitive) to the
power source.
The output is a form C relay. N.O is Blue, N.C. is Violet, and
Common is Green. Selecting the correct output is also
dependant on the operating mode chosen (See Section 4).
Most applications will utilize the N.O. and Common terminals.