CX-DE1200 Delayed Egress Electro Magnetic Lock
INSTA L L AT I O N I NST RU CTI ONS
6. ARMATURE MOUNTING INSTRUCTIONS
Step 1: Close the door, position the EM lock mounting location as close to the upper corner of the door with a minimum gap 1".
Out-Swing
Door Only
Step 2: Place the template against the door and frame and drill holes according to template indications.
Door Frame
Door
2. Drill mark the
screw hole
according to the
template holes
(Door & Frame)
Step 3: Place the mounting plate against the door frame and screw in according to the template holes position.
Door Frame
Temporary mount with self tapping screw
Step 4: Place the armature housing against the door and screw in according to the template holes position
Door Frame
Door
Armature Housing
Page 4 of 9
1"
Door Frame
Door
Out Swing
EZ Interlocking
Mounting Plate
Armature Plate
Mounting Template
Drill 1/2"
Dia. for Cable
Access Hole
Note: Dimensions might change if photocopied.
DE1200-TEMPLATE with FB-DE1200-280
IG-DE1200-280 Ver.1019
Screw #1
Proxy
Trigger
Door
FB-DE1200 Template
Install the mounting plate at 2
slots position first, then make
proper adjustment before
Place Against
marking remaining screws
hole position.
Door Frame
FOLD 90° ON THIS DOTTED LINE
Armature Housing-DE1200 Template
Install the Armature Housing
with 2 screws position
first, then make proper
adjustment before marking
remaining screws hole position.
Place Against Door
Screw #2
Spring
Armature Screw
Door