CAME 319U36EN 설치 매뉴얼 - 페이지 3

{카테고리_이름} CAME 319U36EN에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME 319U36EN 19 페이지. Control panel for 24v gearmotors

You can also connect:
- the open door signal-lamp;
- the cycle lamp;
- the electro lock;
- the 002LB18 for emergency operations in case of power outages.
Types of defi nable commands:
- opening/closing;
-opening/closing with maintained action;
- Partial opening;
- partial stop;
- total stop.
The photocells, after detecting an obstacle, trigger:
- The reopening if the door is closing;
- The partial stop if the door is opening;
TE CHN ICA L DATA
power source 230 V - 50/60 Hz
Maximum allowed power load
power draw when idle
maximum power for 24 V accessories 40 W
circuit insulation class
container material ABS
container protection rating IP54
working temperature -20 / +55°C
4.1 Dimensions, centre distances and anchoring holes
360 W
200 mA
F US E TA B L E
to protect:
Motor/s
Electronic board (line)
Accessories
Command devices (card)
Electro block
fuses for:
10 A-F
3.15 A-F
2 A-F
315 mA-F
2 A-F
(mm)