CAME A 5024 설치 매뉴얼 - 페이지 6
{카테고리_이름} CAME A 5024에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME A 5024 12 페이지. Automation for swing gates

5.5 Mounting
The following are just example applications, given that the space for securing the operator and accessories may vary depending on
the dimensions. It is thus up to the installer to choose the most suitable solution.
Pillar
Anchoring plate
Apply the anchoring plate to the pillar using the back bracket (fig. 1) making sure the A and B measurements are right (Tab. 3) between
the hinge axis and central bore hole on the bracket. The back bracket has several other holes for changing the opening angle of the gate.
N.B.: increasing the B measurement decreases the opening angle resulting in slower peripheral speed and greater motor thrust on the
gate leaf. Increasing measurement A increases the opening angle resulting in greater peripheral speed and reduced motor thrust on the
gate leaf.
With the gate closed apply the anchoring plate to the gate leaf, making sure that the front bracket is lined up horizontally with the back
bracket and ensuring that measurement E is met.
Hinge
Gate leaf closed position
Back bracket
Level the bracket
Tab. 3
Gate leaves up to 3 m
A
Opening
mm
mm
90°
130
130
120°
130
110
Gate leaf up to 5 m
A
Opening
mm
mm
90°
200
200
130°
200
140
Bushing
Anchoring plate
Front bracket
B
C max
E
mm
mm
60
720
50
720
B
C max
E
mm
mm
120
920
70
920
Back swivel-joint