CAME C-BXE24 설치 매뉴얼 - 페이지 16

{카테고리_이름} CAME C-BXE24에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME C-BXE24 20 페이지. Automation for industrial closures
CAME C-BXE24에 대해서도 마찬가지입니다: 매뉴얼 (16 페이지)

CAME C-BXE24 설치 매뉴얼
5.9 Adjusting mechanical end-stops
Make sure the door is in a closed position
and the two crown wheels of the motor
units are both positioned to the left.
N.B.: the gearmotor is already adjusted
in a closed position, namely, the closing
end-stop micro-switch is activated.
Execute a complete opening run manually
or by using the button on the command
board; the two crowns will move to the
right.
Using a screwdriver, raise the end-stop
spring from the crown wheels; manually
move the white crown until it reaches the
opening microswitch and then lower the
spring onto the crowns.
Make a complete closing run and ensure
that the release lever is free from the
safety lever.
NB: the safety lever releases the
emergency release (CMS or C002) only
when the door is closed.
Warning! After making the adjustments
on sectional doors in a closed position,
there may be a gap between the lower
edge of the door and the ground
surface. To eliminate this gap, move the
micrometric lever one step up or down to
lower or raise the door by one centimetre.
16
Microswitch of end-stop in closing
White opening crown
Red closing crown
End-stop spring
Microswitch of end-stop in opening
Safety lever
Release lever
Micrometric lever