Tools and equipment
Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current
regulations. The figure shows some examples of the tools needed by installers.
Types and thicknesses of cables
Connection
230 V power supply to control panel
Motor power supply (V) 24 V
Flashing light
Photocell transmitters
Photocell receivers
Accessories power source
Safety and command devices
Encoder connection
Connecting the antenna
N.B. If cables are of a different length than that shown in the table, determine the cable section based on the actual draw and the
number of connected devices and according the what is set forth in the CEI EN 60204-1 code of regulations.
For connections featuring several loads on the same line (i.e. sequential ones), the dimensions shown on the table must be recon-
sidered according to the total draw and actual distances. When connecting products not featured
in this manual, only refer to the literature accompanying such products.

Standard installation

1) FROG PLUS
2) Control panel
3) Release with customised key
4) Junction box for connecting the gearmotor
5) Antenna
6) Flashing light
7) Key-switch selector
8) Photocells
9) Junction pit
10) Drainage pit
11) Mechanical strike plates
12) Small post for photocells
5
2
9
Cable type Cable length 1 < 10 m
3G x 1.5 mm
3G x 1.5 mm
2 x 1.5 mm
FROR CEI
2 x 0.5 mm
20-22
CEI EN
4 x 0.5 mm
50267-2-1
2 x 0.5 mm
2 x 0,5 mm
TWISTED
RG58
8
6
7
4
11
10
Cable length 10 < 20 m
2
3G x 2.5 mm
2
3G x 0,5 mm
2
2
2 x 1.5 mm
2
2
2 x 0.5 mm
2
2
4 x 0.5 mm
2
2
2 x 0.5 mm
2
2
2 x 0.5 mm
3 x 0.5 mm
max. 10 m
8
4
3
11
1
12
Cable length 20 < 30 m
2
2
3G x 4 mm
2
2
3G x 0,5 mm
2
2 x 1.5 mm
2
2 x 0.5 mm
2
4 x 0.5 mm
2
2 x 1 mm
2
2 x 0.5 mm
2
11
12