CAME V900E 표준 설치 - 페이지 9
{카테고리_이름} CAME V900E에 대한 표준 설치을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME V900E 13 페이지. Automatic traction system for overhead and sectional doors

opening limit switch
Keep the "APRE" button pressed and allow the door to open fully.
Press and release the "ENC/RADIO" button: the signalling LED remains on to indicate that the closing end-stop has been saved.
With the door open, position the end-stop (in the transmission guide) on the sliding runner and secure it with the screws.
Set dip-switch 1 to OFF.
Note: if the LED indicator begins to flash rapidly after dip 1 has been reset, it is necessary to repeat the procedure from the start.
NOTES
After having programmed and switched dip 1 to OFF, use the "AP/CH" key to check proper gate opening and closing.
During programming, make sure the closing end-stop has been previously memorised, otherwise the data will not be memorised.
Should the encoder malfunction or were it incorrectly connected to the opening or closing control, the motor will move briefly
and then stop. The LED indicator will indicate the irregularity by flashing slowly and continuously. In this case it is necessary to
disconnect power supply from the control panel and then reconnect it.
T.C.A.
SENS.
AP / CH
ON
1
2
E -
ENC/RADIO
APRE
AF
26V17V 0V
M N
FUS. CENTR.
315mA
ZL56
FUS. MOTORE 7.5A
+ E -
26V17V 0V
M N
FUS. CENTR.
315mA
ZL56
T.C.A.
FUS. MOTORE 7.5A
ON
1
2
+ E -
T.C.A.
SENS.
APRE
ENC/RADIO
AP / CH
ON
1
2
AF
SENS.
ENC/RADIO
AP / CH
APRE
AF
9