CAME ZL19N 설치 매뉴얼 - 페이지 9

{카테고리_이름} CAME ZL19N에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME ZL19N 17 페이지. Control panel for 24v gearmotors

CAME ZL19N 설치 매뉴얼

Command devices

Stop button ((N.C.) contact.)
Gate stop button with exclusion of automatic closing, to resume movement
press command button or transmitter button.
If unused set DIP switch n.9 to ON.
Key-switch selector and/or opening button N.O. contact)
- Command for gate opening.
Key switch selector and/or opening button (N.O. contact)
- Opening a gate leaf for pedestrian passage (opening M2 motor).
Key-switch selector and/or opening button (N.O. contact)
- Gate opening and closing commands, pressing the button
or turning the key-switch selector,
movement or stops depending on selection made on the DIP
switches (see selecting functions, DIP switches 2-3) Jumper
OFF (p. 4 point 20).
Key switch selector and/or opening button
Gate-leaf closing command. Jumper ON (p. 4 point 20).

6.1 Electrical connection for photocells functionalities test

Delta
(
)
With each opening and c
losing command, the card checks the effi ciency of the safety devices
(i.e. photocells). Any anomalies in the photocell is notifi ed by the
fl ashing LED (PROG) on the control panel, and cancels any other
command from the transmitter or button.
Electrical connection to work the photocells safety test:
- the transmitter and receiver, must connected as shown in the diagram:
- Set Dip-switch 3 to ON to activate the test.
IMPORTANT:
When you activate the safety test, CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2-C3, 2-C1 and, if the contacts are
unused, exclude them via Dip-switch 8 and 10.
the gate inverts its
contact) -
(N.O.
DIR
(
)