INSTALLATION & WIRING INSTRUCTIONS
Installation
Mounting of the device requires a standard gang box. Only SQUARE CORNER mud-rings fit these devices.
Wiring
TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WORKING WITH OR NEAR HIGH VOLTAGE
The WOS Series Line Voltage sensors are equipped with #14 AWG stranded leads. Use appropriate sized wire-nuts to connect the wires
to the incoming load terminations; for installation with field-installed conductors of 60ºC minimum rating.
WOSSDU1-P-TW
Neutral
Wht
Line
Blk
Blk/Wht
Load
Grn
Ground
(required)
DIP Switches
A bank of eight DIP switches and two rotating controls can be used to manually setup and configure the sensor.
DIP #
1
Voice Detection
2
Motion Detection Sensitivity
3
Detection LED
4
Auto or Manual ON
5
Photocell Inhibit
6*
Photocell Control
7
Manual Override Button
8
Settings Input
*2-Pole models only
Ph. 877-873-2797
®
Installation
CAUTION
WOSSDU*-P-TW
FUNCTION
Disabled
High
Disabled
Occupancy (Auto-On)
Disabled
Inhibit Primary Pole Only
Disabled
IR Handheld (WR-3110)
www.DouglasLightingControls.com
Wall Switch Occupancy Sensor Retrofit
Line Voltage with Neutral
WOSSDU2-P-TW
Neutral
Wht
Line
Blk
Blk/Wht
Load
Grn
Ground
(required)
ON
OFF
Enabled
Normal
Enabled
Vacancy (Manual On)
Enabled
Inhibit Both Poles
Enabled
DIPS & Dials
Blu
Line
Blu/Wht
Load
DEFAULT
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
2018-10-16